Perfect-aire 10000PPAC Manuel d'utilisateur Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 15
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
AIR
CONDITIONER NOT
COOLING ROOM, OR NOT
BLOWING COLD AIR
• Be sure unit is not too large or too small for the area of the room.
• Verify that all doors, windows, curtains and any other openings are closed off. Verify nothing is obstructing the
airflow to/from the unit and louvers such as curtains, etc.
• Allow enough time for room to cool, especially if outside temp is very high.
• Check that the filter is not dirty and louvers are open all the way and blowing in the direction desired.
• Check that unit is set to Cool Mode and that temperature is down enough (but not too low).
• If unit is near a heat source, such as a stove, etc., then relocate unit.
• If air coming from unit is cool to the touch, then unit is working properly; please double check the first three
bullet points above.
• If using Follow Me remote feature, move remote away from unit.
• Unplug unit for at least 5 minutes. Follow Reset instructions on plug.
AIR CONDITIONER
CYCLING ON AND OFF TOO
FREQUENTLY OR NOT ENOUGH
• Be sure unit is not too large or too small for the area of the room.
• Make sure nothing is blocking the louvers.
• Make sure there is no dirt or debris inside the unit or on the filters.
AIR CONDITIONER COOLING BUT
ROOM IS TOO WARM - ICE
FORMING ON COOLING COIL
BEHIND DECORATIVE FRONT
• Outdoor temperature is below 64ºF (18ºC). To defrost the coil, set to Fan Only mode.
• Air filter may be dirty. Clean filter. Refer to Care and Maintenance section. To defrost, set to Fan Only mode.
• Thermostat is set too cold for night-time cooling. To defrost the coil, set to Fan Only mode. Then, set
temperature to a higher setting.
UNIT WILL NOT TURN ON
• Reset circuit breaker. Make sure there are not too many items (ie lamps, TV’s, etc.) working off the
same breaker.
• Check plug connection.
• If plug is operating on an on/off switch, be sure that the switch is ‘on’.
• Try plugging unit into another outlet.
• Unplug unit for at least 5 minutes. Follow Reset instructions on plug.
UNIT BLOWS FUSES OR POPS
CIRCUIT BREAKER
• Make sure there are enough available amps on the circuit for the air conditioner.
• Large units which run on a 230v will require a dedicated 20 or 30 amp circuit.
REMOTE SENSING / FOLLOW ME
DEACTIVATING PREMATURELY
• Remote control not located within range. Place remote control within 20 ft and 180º radius of the front
of the unit.
• Remote control signal obstructed. Remove obstruction.
Issue Possible Solutions
AIR CONDITIONER IS
MAKING NOISES
• Check to be sure the unit is free from debris. Verify nothing is obstructing the unit.
• Check the fan blade for cracks or chips.
• Make sure the window slider kit is properly and securely mounted inside the window.
• Clean the air filter.
TROUBLESHOOTING TIPS
Before calling for service, please review the chart below.
NOTE: A highly recommended troubleshoot for any issue in general consists of turning off unit and unplugging for 5 minutes.
It is also recommended to try another wall outlet.
13
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15

Commentaires sur ces manuels

Pas de commentaire